GL200 User Manual
TRACGL200UM001 - 10 -
Example of OUT pin drive a LED
Example of OUT pin drive a relay
If the digital output is used to drive a relay, a catch diode is showed across the relay coil, this is
necessary to prevent damage to the digital output when the relay is turned off. Many modern relays
come with this diode pre-installed internal to the relay itself. If the relay has this diode, insure the
proper relay polarity connected is used. If this diode is not internal, it should be added externally. A
common diode such as a 1N4004 will work in most circumstances.